Please use this identifier to cite or link to this item: http://hdl.handle.net/123456789/3164
DC FieldValueLanguage
dc.contributor.authorSuaimi, Muhammad Khairul Asyrafaen_US
dc.contributor.authorRashid, Amir Mustakim Aben_US
dc.contributor.authorNasution, Ahmad Kafrawien_US
dc.contributor.authorSeng, Gan Hongen_US
dc.contributor.authorKadir, Mohammed Rafiq Abdulen_US
dc.contributor.authorRamlee, Muhammad Hanifen_US
dc.date.accessioned2022-07-18T13:18:12Z-
dc.date.available2022-07-18T13:18:12Z-
dc.date.issued2022-05-
dc.identifier.issn01279696-
dc.identifier.urihttp://hdl.handle.net/123456789/3164-
dc.descriptionScopusen_US
dc.description.abstractInternal fixators are commonly used to treat long bone fractures, its aim is to provide interfragmentary compression, allow limited micromotion and provide stability to the bone for ambulation. However, complications such as non-unions, malunions and broken implant, can occur due to the complexity of mechanical force acting on the bone-plate models. Therefore, this study is proposed to investigate the biomechanical characterization of plate design on a tibia bone using finite element method. Two different designs; 1) locking compression plate (LCP) and dynamic compression plate (DCP) were simulated by using Marc.Mentat software. From the findings, the LCP have lower peak von Mises stress (VMS) distribution of 160 MPa compared to DCP with VMS value of 232 MPa. Surprisingly, the VMS of DCP plate system have exceed the yield strength of stainless steel (215 MPa) which translate to higher risk of failures. Moreover, the DCP plate system shows 50% lower stability compared to the LCP plate system, which has the peak displacement at 0.98 mm compared to the DCP bone at 1.53 mm. In conclusion, the LCP provides better stability and stress distribution up to 45% differences as compared to the DCP.en_US
dc.language.isoenen_US
dc.publisherPenerbit UTM Pressen_US
dc.relation.ispartofJurnal Teknologien_US
dc.subjectDisplacementen_US
dc.subjectDynamic Compression Plateen_US
dc.subjectLocking Compression Plateen_US
dc.subjecttibiaen_US
dc.subjectVon Mises Stressen_US
dc.titleBIOMECHANICAL EVALUATION OF LOCKING COMPRESSION PLATE (LCP) VERSUS DYNAMIC COMPRESSION PLATE (DCP): A FINITE ELEMENT ANALYSISen_US
dc.typeNationalen_US
dc.identifier.doi10.11113/jurnalteknologi.v84.16687-
dc.description.page125 - 131en_US
dc.volume84 (3)en_US
dc.description.typeArticleen_US
item.languageiso639-1en-
item.openairetypeNational-
item.grantfulltextopen-
item.fulltextWith Fulltext-
Appears in Collections:Faculty of Data Science and Computing - Journal (Scopus/WOS)
Show simple item record

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.