dc.description.abstract | Distributed Generation (DG) has become the world's primary focus for solving the energy crisis and pollution. Therefore, it is crucial to investigate the impacts of DG on the existing radial distribution network to ensure the reliability and efficiency of the network. This paper presents the impact of DG in terms of voltage profile and power losses in the Malaysia distribution network. A 33/11kV Medium Voltage (MV) distribution network based in PPU Bakar Batu and PPUCentury, Johor Bharu was modelled and simulated using PSCAD/EMTDC simulation software. Several cases with different location of DG placement and size of DG were carried out in this study. The simulation results showed an improvement of voltage profile within the allowable limit of 0.95p.u and 1.05p.u and a minimization of power losses after DG was installed in the network. The suggestions for the optimal location for DG installation was analyzed based on the results of the pre and post interconnection of DG. | en_US |
dc.relation.ispartof | International Journal of Electrical Engineering and Applied Science | en_US |
dc.subject | distribution generation (DG) | en_US |
dc.title | Impact of DG on Voltage Profile and Power Losses for 33/11kV PPU Bakar Batu and PPU Century (Johor Bharu) using PSCAD Software | en_US |
dc.type | International | en_US |
dc.description.page | 32-38 | en_US |
dc.volume | 5(1) | en_US |
dc.description.type | Article | en_US |
item.openairetype | International | - |
item.grantfulltext | open | - |
item.fulltext | With Fulltext | - |
Appears in Collections: | Journal Indexed Era/Google Scholar and Others - FBKT |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
6101-Article Text-17478-2-10-20220801.pdf | 1.01 MB | Adobe PDF | View/Open |
Google ScholarTM
Check
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.